SKU: PCDVP023000
Product Type: PLC Programming / Communication Cable
Connector Type: DB9 Male to Mini DIN 8P Serial Cable
Cable Length: 3 Meter
Brand: Smidnya / Smidmart
The PC - Delta PLC DVP Series Programming Cable (3 Meter) is a dedicated communication cable used for programming and data transfer between a PC/laptop and Delta DVP Series PLCs. It supports reliable communication for:
Program upload / download
PLC monitoring
Commissioning
Maintenance and troubleshooting
Its 3-meter length provides flexibility during field setup and service work. The cable is designed for stable communication in industrial environments.
This cable is commonly used for:
PLC program upload/download
Online monitoring of PLC data
Machine commissioning
Parameter setting
Maintenance & troubleshooting
Service support in control panels
Delta DVP Series PLCs (communication port must match Mini DIN 8P interface)
PC/Laptop with RS-232 (DB9) COM port
If no COM port is available (common in modern laptops), use:
USB to RS232 converter (recommended industrial-grade adapter)
Important: Compatibility depends on the PLC communication port type. Always verify the port before connection.
Connector A: DB9 Male
Connector B: Mini DIN 8P Male
Cable Type: Serial communication / programming cable
Length: 3 Meter
Use the official pinout / mapping image for this cable in this section (recommended to attach the image in KB article attachments or embed it in article body).
Always verify PLC/HMI communication port pinout before connecting.
Incorrect pin mapping or forced insertion may cause communication failure or port damage.
Turn off/idle the machine safely (as per plant SOP).
Connect the Mini DIN 8P end to the Delta DVP PLC communication port.
Connect the DB9 Male end to the PC COM port.
Open the Delta PLC programming software.
Select the correct COM port in software settings.
Configure communication parameters (baud rate, parity, stop bits, etc.) as required.
Click Connect/Test Communication.
Start upload/download/monitoring as needed.
Connect a USB to RS232 converter to the laptop.
Install converter driver (if required).
Connect the cable DB9 end to the converter.
Connect Mini DIN 8P end to the PLC.
Open Device Manager and confirm assigned COM port number.
Select the same COM port in Delta software.
Test communication and proceed.
Possible causes
Wrong COM port selected
Wrong communication settings
Loose connection
Unsupported converter / faulty adapter
Incorrect pinout assumption
Solutions
Check and select the correct COM port
Verify baud rate / parity / stop bit settings
Reconnect both ends firmly
Test with another USB-RS232 converter
Verify PLC port type and cable compatibility
Restart software and reconnect
Possible causes
USB-RS232 driver not installed
Converter not detected
Faulty USB port/cable
Solutions
Install / reinstall the USB-RS232 driver
Try another USB port
Check Device Manager for port detection
Replace converter if needed
Possible causes
Loose DB9 connector
Noise interference from power cables/VFD lines
Poor quality USB-RS232 converter
Damaged cable
Solutions
Tighten and secure connectors
Route communication cable away from high-power cables
Use shielded / industrial-grade adapter
Inspect cable for cuts, bends, or connector damage
Test on another PC/laptop
Solution
Use a USB to RS232 converter
Prefer converters with stable drivers for industrial use
Possible causes
PLC in RUN mode restrictions (depending on software/PLC settings)
Incorrect station/address settings
Program/software version mismatch
Solutions
Check PLC mode and connection settings
Confirm software communication parameters
Retry with correct PLC model selection in software
Do not force connector insertion
Check connector orientation before plugging in
Avoid sharp bends / twisting of cable
Keep away from moisture, oil, and physical crushing
Disconnect carefully after use
Store in a dry, dust-free place
| Parameter | Specification |
|---|---|
| Product Name | PC - Delta PLC DVP Series Programming Cable - 3 Meter |
| SKU | PCDVP023000 |
| Cable Type | PLC Programming / Communication Cable |
| Connector A | DB9 Male |
| Connector B | Mini DIN 8P Male |
| Length | 3 Meter |
| Application | Delta DVP PLC Programming, Data Transfer, Monitoring |
| Usage Environment | Industrial automation setup / service / maintenance |
Not necessarily. It is intended for Delta DVP Series PLCs with matching communication port type. Please verify the PLC port before purchase/use.
Yes, if the laptop has a DB9 serial port. Otherwise, use a USB to RS232 converter.
Common reasons include wrong COM port, wrong communication settings, or unsupported USB-RS232 converter. Follow the troubleshooting steps above.
This cable is generally used for programming, monitoring, setup, and troubleshooting. For permanent communication setups, confirm application requirements and interface specifications.
A 3-meter cable is generally suitable for programming/service use. In noisy environments, routing and shielding quality matter.
Contact support if:
You are unsure about PLC port compatibility
Communication fails after trying the troubleshooting steps
You need the correct USB-RS232 converter recommendation
You want a cable for a different PLC/HMI model
You need installation / commissioning assistance