The Leuze AC-AN-A (Part No. 63000701) is a precision-engineered actuator designed for normal-duty applications where reliability, compact size, and stainless steel construction are essential. This angled actuator is ideal for integration into a wide range of industrial automation setups.
Parameter | Details |
---|---|
Part Number | 63000701 |
Model Name | AC-AN-A |
Dimensions (W × H × L) | 28 mm × 11.8 mm × 30.7 mm |
Net Weight | 10 g |
Mounting Type | Through-hole mounting |
Mounting Bore Holes | In key direction |
Actuator Design | Angled |
Application | Normal duty |
Material | Stainless steel |
Classification Standard | Code |
---|---|
Customs Tariff Number | 85369095 |
ECLASS 5.1.4 / 8.0 | 27279216 |
ECLASS 9.0 to 15.0 | 27272606 |
ETIM 5.0 to 10.0 | EC001487 |
All dimensions in millimeters (mm):
Key Dimensions: 2, 4, 6.7, 9, 10.5, 14.5, 15, 21, 28
Radius: R 220
Bore Diameter: Ø4.5 mm
Clearances: ≥ (minimum clearances shown in technical diagram)
Compact design for space-constrained installations
Angled actuator for better reach and actuation geometry
Durable stainless steel construction for corrosion resistance
Lightweight (only 10 g) – reduces load on mounting surfaces
Normal duty rated for general industrial usage
Standardized mounting with through-hole and key-alignment
International classification codes for ease in inventory and compliance
Supports digital twin systems through ETIM/ECLASS entries
High precision with tightly specified dimensions
Manufactured by Leuze, a trusted industrial automation brand
Issue | Possible Cause | Suggested Solution |
---|---|---|
1. Actuator does not move | Misalignment | Verify proper installation per drawing |
2. Mounting holes do not fit | Wrong key direction | Realign according to key slot spec |
3. Loose mounting | Under-tightened screws | Check torque settings |
4. Rust or corrosion | Improper environment | Use only in specified normal-duty conditions |
5. Breakage | Excessive mechanical load | Verify force limits |
6. Vibrating actuator | Weak fastening | Re-tighten mounting |
7. Incorrect bore size | Wrong part ordered | Confirm Ø4.5 mm bore match |
8. Sensor not triggered | Misplaced actuator | Realign actuator angle/distance |
9. Missing signals | Wiring error in system | Inspect electrical setup |
10. Deformation | Heat exposure | Avoid excessive ambient temperatures |
11. Scratches or dents | Rough handling | Improve transport/storage care |
12. Wear marks | Continuous overuse | Inspect cycle count vs. rated life |
13. Actuator stuck | Foreign debris | Clean mounting area |
14. Assembly mismatch | Wrong actuator type | Confirm part number: 63000701 |
15. No documentation | Missing label | Refer manufacturer site (www.leuze.com) |
16. Delay in movement | Mechanical friction | Lubricate or clean mount contact |
17. Over-tightened screws | Thread damage | Use torque wrench |
18. Stainless steel discoloration | Chemical exposure | Use protective environment |
19. Interference with other parts | Crowded setup | Ensure spacing per dimensioned drawing |
20. Product not recognized in ERP | Missing classification | Use ECLASS & ETIM codes correctly |
21. Frequent replacements | Wrong duty class | Use actuator only for normal duty |
22. Sensor signal drops | Loose sensor-actuator gap | Adjust distance/alignment |
23. Assembly confusion | Similar parts mixed | Label all actuators during storage |
24. Cannot access mounting holes | Obstructed access | Redesign fixture if needed |
25. Vibration noise | Poor base mounting | Add damping material |
26. Premature wear | Non-aligned actuator path | Check for skewed movement |
27. Part bends on use | Excessive torque | Validate movement mechanics |
28. Surface pitting | Moisture ingress | Ensure dry working condition |
29. Sticking after long rest | Surface corrosion | Operate periodically to avoid rust |
30. Procurement mismatch | Wrong code used | Double-check: ECLASS 27272606 / ETIM EC001487 |